Vapor Barrier On Concrete Roof Deck

Flat Concrete Roof Insulation Roof Insulation Concrete Roof Concrete Ceiling

Flat Concrete Roof Insulation Roof Insulation Concrete Roof Concrete Ceiling

Polyethylene Under Concrete Slabs Concrete Slab Concrete Slab Foundation Slab Foundation

Polyethylene Under Concrete Slabs Concrete Slab Concrete Slab Foundation Slab Foundation

Image Result For Precast Concrete Roof Detail

Image Result For Precast Concrete Roof Detail

Extensive Vegetated Roof System Thickness Concrete Roof Google Search Green Roof System Green Roof Roofing Systems

Extensive Vegetated Roof System Thickness Concrete Roof Google Search Green Roof System Green Roof Roofing Systems

Bsd 106 Understanding Vapor Barriers Exterior Insulation Roof Cladding Rigid Insulation

Bsd 106 Understanding Vapor Barriers Exterior Insulation Roof Cladding Rigid Insulation

Dry Basements Depend On Durable Vapor Barriers That Isolate Slabs Dry Basement Vapor Barrier

Dry Basements Depend On Durable Vapor Barriers That Isolate Slabs Dry Basement Vapor Barrier

Dry Basements Depend On Durable Vapor Barriers That Isolate Slabs Dry Basement Vapor Barrier

Here s a key takeaway all vapor retarders block air but not all air barriers block vapor diffusion.

Vapor barrier on concrete roof deck.

This can be accomplished either because of the local climate or as a result of design principally through the use of rigid insulation installed above the roof deck or air impermeable spray foam insulation installed. The key is to keep the roof deck the principle condensing surface in roof assemblies sufficiently warm throughout the year. In a low slope roof assembly the vapor retarder is normally installed under the primary roof insulation. Therefore one will often see it installed directly on a roof deck such as a concrete or wood deck or on a continuous substrate such as gypsum board or wood panels that is installed directly over a metal deck.

In reroofing situations where the existing roof deck is known to be lightweight structural concrete or there is evidence of concrete deck related moisture problems nrca maintains its earlier recommendation for using a high bond strength vapor retarder adhered directly to the roof deck. A vapor retarder is commonly installed on the warm interior side of a roof or wall. A vapor retarder is a material or system that is designed as part of the roof system to substantially reduce the movement of water vapor into the roof system where it can condense. Vapor barriers installed on the interior of assemblies prevent assemblies from drying inward.

If a roof system is installed over a concrete deck without a vapor barrier the moisture in the concrete will likely dry into the roof insulation. Another exception is a class i vapor retarder should be installed over a new concrete deck to prevent the moisture in the concrete from drying into the roof system. Rolling out a course of the new vapor barrier. This method is shown in the image above.

From a practical standpoint a vapor retarder of less than 0 01 perm is effectively a vapor barrier almost no moisture passes through to the roof system above. Vapor barriers were originally intended to prevent assemblies from getting wet. The old vapor barrier was attached with hot asphalt and it s really fused to the concrete deck. Exceptions to this idea include roofs over indoor swimming pools or other high humidity producing activities and over new concrete roof decks to prevent the moisture in the concrete from drying into the roof system.

When we use a vapor retarder in a roof system it will also act as an air barrier as long as it is sealed at all perimeters and penetrations and is tied to the wall air barrier. However they often prevent assemblies from drying. Roofs over concrete decks should always have a vapor barrier installed. Concrete contains a significant amount of moisture and there is no test to accurately tell if the concrete is dry enough to install the roof on top of it.

The midwest roofing contractors association mrca is advising a vapor retarder of less than 0 01 perm is necessary over new concrete roof decks. Everyone knows that water in roof systems is never a positive.

Image Result For Roof Section Metal Decking Membrane Roof Roofing Roof Detail

Image Result For Roof Section Metal Decking Membrane Roof Roofing Roof Detail

Rr 0404 Roof Design Building Science Corporation Instead Of Installing Rigid Insulation Above The Roof Deck To Roof Design Roof Cladding Rigid Insulation

Rr 0404 Roof Design Building Science Corporation Instead Of Installing Rigid Insulation Above The Roof Deck To Roof Design Roof Cladding Rigid Insulation

If You Don T Have A Low Water Concrete Or If You Don T Have An Effective Vapor Barrier And Capillary Break Install A Walking The Plank Epoxies Low Water

If You Don T Have A Low Water Concrete Or If You Don T Have An Effective Vapor Barrier And Capillary Break Install A Walking The Plank Epoxies Low Water

Flat Roof Deck Arrow Roofing An Isle Of Man Based Roofing Services Roofingstructure Flat Roof Construction Flat Roof Flat Roof Extension

Flat Roof Deck Arrow Roofing An Isle Of Man Based Roofing Services Roofingstructure Flat Roof Construction Flat Roof Flat Roof Extension

Source : pinterest.com